Furrion · Arctic 8 and 10 cu. ft. 12-volt refrigerators listed in CCD-0008122
1 flashCompressor controller voltage fault
One diagnostic LED flash indicates that the compressor controller sees voltage outside its operating range.
What it means
Plain-English answer
The Furrion service manual maps one flash to a voltage fault. Low battery voltage, voltage drop, a converter problem, wiring, or a switch in the RV supply can prevent the compressor from starting reliably.
Owner-safe checks
What to check first
- 01
Turn the refrigerator off and check the RV battery monitor.
- 02
Connect approved shore power and confirm the converter is charging the battery.
- 03
Charge the batteries fully and check accessible battery-disconnect controls.
Safety boundary
Stop and call a technician when
- Do not access or measure the compressor control board unless qualified.
- Arrange RV electrical or appliance service if the flash returns with a charged battery.
Primary reference
Check the exact manual
Applicability: Arctic 8 and 10 cu. ft. 12-volt refrigerators listed in CCD-0008122. The data plate and specification letter determine which procedure is correct.
Open Furrion Arctic troubleshooting and service manual ↗Source reviewed August 2026